XGN2-12KV metal closed box combined switchgear

Description

XGN2-12KV Inlet and outlet equipment of metal closed box combined switchgear

Introduction of metal closed box combined switchgear

XGN2-12 box-type fixed metal closed box combined switchgear (referred to as switchgear) is used for receiving and distributing electric energy in 3.6, 7.2, 12kv three-phase AC 50Hz systems, suitable for frequent operation occasions, and its busbar system is a single busbar (and can be derived single bus with bypass and double bus structure).

The switchgear meets the requirements of the national standard GB3906-91 (3-35kv AC metal-enclosed switchgear) and the national standard IEC298, and has two proposed “five-proof” locking functions.

The main switch of the switch cabinet adopts ZN28-12 series vacuum circuit breaker, equipped with CDI7 series electromagnetic operating mechanism or CT19 series spring operating mechanism, and the isolating switch adopts GN30-12 rotary isolating switch or GN22-12 high current isolating switch series.

Environment condition:

1:Ambient temperature: the upper limit is +40℃, the average value measured within 24 hours does not exceed 35℃, and the lower limit is -10℃;
2: Altitude: the altitude does not exceed 1000 meters;
3:relative humidity: the daily average does not exceed 95%, and the monthly average does not exceed 90%;
4:seismic intensity: no more than 8 degrees;
5:water vapor pressure: daily average no more than 2.2 kPa, monthly average no more than 1.8 kPa;
6:surrounding environment, no fire and explosion danger, serious pollution, chemical corrosion and severe vibration on site.

ordering instruction:

When ordering, the user should provide the following information:

Main circuit scheme number and primary system diagram and layout diagram;

Secondary circuit wiring diagram and terminal arrangement diagram, if there is no terminal arrangement diagram, according to the manufacturer’s regulations;

Type, size and number of electrical components in switchgear;

The materials and specifications of the main busbar and branch busbar, if not available, shall be specified by the manufacturer;

The special environmental conditions for the use of the switchgear should be indicated when ordering;

When accessories and spare parts are required, the model and quantity should be indicated