XGN66A-12 box-type fixed distribution cabinets

Box-type fixed distribution cabinets. XGN66A-12 fixed metal-clad movable switchgear (hereinafter called switchgear), is used in the system of rated voltage 3.6- 12KV three-phase, AC50/60Hz, to receive and distribute electricity.

Description

XGN66A-12 box-type fixed distribution cabinets Power distribution box switch cubicle control cabinet Inlet and outlet cabinet

Introduction box-type fixed distribution cabinets

Box-type fixed distribution cabinets. XGN66A-12 fixed metal-clad movable switchgear (hereinafter called switchgear), is used in the system of rated voltage 3.6- 12KV three-phase, AC50/60Hz, to receive and distribute electricity. Suits for frequently switching, or reconstruction of switchgear with oil type breaker.

Busbar system is single busbar system or single busbar with branches. Comply with GB3906 AC metal-enclosed switchgear and controlgear for rated voltages above 3 kV and up to and including 35 kV. DL/T404 Purchase technical specifications is for indoor AC high voltage switchgear. IEC60298 AC metal-enclosed switchgear and controlgear is for rated voltage above 1 kV and up to and including 52 kV standard.

The switchgear has good figure, small size provides complete prevention of the wrong operation. The main switch o the switchgear adopted VS1-12 or ZN28-12 vacuum circuit breaker type GN30-12 or GN19-12 isolator, and JN15-12 earth switch.

Environment condition:

1:Ambient temperature: the upper limit is +40℃, the average value measured within 24 hours does not exceed 35℃, and the lower limit is -10℃;
2: Altitude: the altitude does not exceed 1000 meters;
3:relative humidity: the daily average does not exceed 95%, and the monthly average does not exceed 90%;
4:seismic intensity: no more than 8 degrees;
5:water vapor pressure: daily average no more than 2.2 kPa, monthly average no more than 1.8 kPa;
6:surrounding environment, no fire and explosion danger, serious pollution, chemical corrosion and severe vibration on site.

ordering instruction:

1: Main circuit plan number, use and single-line system diagram, rated voltage, rated current, rated short-circuit breaking current, distribution room layout and switchgear arrangement diagram, etc.
2: Requirements for control, measurement and protection functions of switchgear and requirements for other locking and automatic devices.
3: The model, specification and quantity of the main electrical components in the switchgear.
4: If a bus bridge connection is required between switchgear or incoming cabinets, provide specific requirements data such as the rated carrying capacity of the bus bridge, the span of the bus bridge, and the height from the ground.
5: When the switchgear is used under special environmental conditions, it should be detailed when ordering.

We also supply the following switchgears:

Rated votlage 40.5KV switchgear(for 33KV system)
KYN61-40.5 withdrawout metal-clad and metal-enclosed switchgear
KYN10-40.5AC drawout metal clad switchgear
KYN1-40.5 AC withdrawable metal-clad enclosed switchgear
XGN-40.5 fixed AC metal-enclosed switchgear
GBC-40.5 Handcar HV switchgear
Rated voltage 24KV switchgear(for 22KV,20KV, 15KVsystem)
KYN-24 withdrawable metal-clad switchgear
HRM6-24 Ring net SF6 circuit breaker switchgear ( for 22KV,20KV, 15KVsystem )
Rated votlage 12KV switchgear(for 11KV,10KV,6.6KV system)
KYN28A-12 withdrawable metal-clad enlosed switchgear
XGN-HKGN8-12 Fixed metal clad enclosed switchgear (for 11KV,10KV,6.6KV system)
HXGN-12 Ring Net Vacuum circuit breaker switchgear ( for 11KV,10KV,6.6KV system )
XGN15-12 Ring Net SF6 circuit breaker switchgear (for 11,10,6.6KV system)
Rated voltage 0.4KV low voltage switchgear(380V,400V,433v,440V system)
GCK LV withdrawable switchgear
GCS LV withdrawable switchgear
HMNS LV withdrawable switchgea
GGD LV distribution cabinet
XL-21 Power distribution box
MOTO Start swichgear
Modula 630K sersies of standard LV distribution box