ZN12 40.5KV 2000A Three-phase AC indoor high-voltage vacuum circuit breaker

Product Structural features:

1.The operating mechanism is introduced the technique of operating mechanism from Siemens 3AF vacuum circuit breaker,the operating mechanism is integrated with vacuum circuit breaker,with characteristics of short transmission routes,less chains and high transmission efficiency.
2.This operating mechanism adopts spring type,it can be operated by AC or DC,also can be operated by manual.

Description

ZN12 40.5KV 2000A Three-phase AC indoor high-voltage vacuum circuit breaker

overview of indoor high voltage vacuum circuit breaker

ZN12 series of indoor high voltage vacuum circuit breaker is with rated voltage of 40.5kV,three-three phase A.C.50(60) Hz indoor high voltage switch equipment. Clich here for more types of this item.

T he structure of this kind of circuit breaker is simple but with strong breaking capability.It  is suitable for application in the mining industry,substations and power transmission and distribution systems for controlling and protecting the switch.

Especially suitable foe the industry which requires frequently operations like metallurgy fields,electric arc steel plant to control and protect the equipment.

This kind of vacuum circuit breaker can be assembled with truck which can be suitable for many kinds of switchgear such as JYN1,GBC etc

Our products are widely used in:

1 – Transformers and distribution substations
2 – Generator control and protection
3 – Capacitor bank control and protection, etc

Product Structural features:

1.The operating mechanism is introduced the technique of operating mechanism from Siemens 3AF vacuum circuit breaker,the operating mechanism is integrated with vacuum circuit breaker,with characteristics of short transmission routes,less chains and high transmission efficiency.
2.This operating mechanism adopts spring type,it can be operated by AC or DC,also can be operated by manual.

Product use environment:

Ambient temperature:-10ºC-+40ºC
Relative humidity:The average humidity of a day should be no more than 95%. The average humidity of a month should be no more than 90%.
Earthquake intensity: not exceed 8 degrees.
Saturated vapor pressure the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more
Than1.8Kpa;
The height above sea level:≤1000 m (Except special requirements)
It should be installed in the places without fire, explosion, serious filth, and chemical erosion and violent vibration.