Power Transformer Losses – Different Types of Losses in a Transformer

Transformer Losses Power transformer losses refer to the loss of electrical…

Transformer Losses

Power transformer losses refer to the loss of electrical energy during the operation of a transformer. This is usually due to current flowing through the core, which produces heat and causes energy losses. The higher the load current, the greater the transformer losses.

Full-load transformer losses are composed of two parts: core losses and load losses. Core losses are caused by hysteresis and eddy currents in the core as it magnetizes and demagnetizes due to changing current passing through it.

Load losses occur when current flows through windings, causing resistance and generating heat.

Stray losses are also generated in this process due to magnetic field leakage. All these factors contribute to transformer losses. Which reduce the life of the transformer by increasing its operating temperature beyond acceptable levels.

Power Transformer Losses

Type of Transformer Losses

Transformer losses come in four different types: Iron Losses, Copper Losses, Hysteresis Power Losses and Eddy Current Losses. Iron losses are the result of the magnetic core’s resistance to magnetic flux changes. Which causes a small amount of power to be dissipated as heat. The losses of Copper are caused by resistance in the primary and secondary windings of the transformer. Resulting in a larger amount of energy being lost as heat.

Transformer Losses

Hysteresis power losses occur due to the core’s reluctance to change its magnetization direction quickly, causing additional power loss. Lastly, eddy current losses occur when induced currents flow within the transformer core material due to changing magnetic fields(EM field), resulting in yet more power loss in the style of heat. The combination of these four types of transformer losses can cause significant amounts of energy dissipation that must be accounted for when designing a new or existing system.

Iron Losses in Transformer

The losses of iron in Transformer are the power loss in the transformers due to the flux being alternated. These losses occur at full load, and can be divided into two types: hysteresis loss and eddy current losses. Hysteresis loss is caused by residual magnetism when an changing EM field is applied, while the losses of eddy current occur from circulating currents induced from changing flux. Both of these losses contribute to the overall power loss in the transformers.

Iron Losses in Transformer

In order to reduce the losses of iron, transformer designers look for materials that have low hysteresis losses and the losses of eddy current. One way they do this is by using materials with higher permeability, which reduces the amount of energy needed to produce a given flux level. By reducing these types of losses, transformer efficiency can be increased significantly.

Copper Losses in Transformer

The losses of Copper in transformers refer to the amount of power dissipated by the current flowing through its primary and secondary windings. This power is dissipated in the form of heat, which is proportional to the square of the current. The amount of power dissipated depends on both the primary and secondary winding currents, making it important for transformer designers to carefully consider these factors when designing their transformers.

The losses of Copper are usually one of the biggest contributors to energy loss in the transformers, so it is essential that all possible measures are taken to reduce them. By reducing copper losses, more efficient transformers can be produced with less wasted energy.

Hysteresis Losses in Transformer

The losses of hysteresis power occur in transformers due to the magnetic properties of their core material. Hysteresis loss is the energy loss associated with the flux reversal which takes place when the polarity of a transformer’s applied voltage reverses. Whenever this flux reversal occurs, power is dissipated in the form of heat. In other words, hysteresis losses are caused by a transformer having to work harder to reverse its own magnetic field when its current changes direction.

Hysteresis Losses in Transformer

Consequently, more power is dissipated during each flux reversal and results in a loss in a transformer’s efficiency. To reduce the hysteresis power losses, manufacturers use special magnetic materials that exhibit low hysteresis loss and require less power to reverse their magnetism. With this, fewer losses are incurred and overall transformer efficiency improves.

Eddy Current Losses in Transformer

Eddy current losses in the transformer are caused by the alternating current flowing through the core of the transformer. This alternating current generates eddy currents which create a flux that opposes the primary flux, thus resulting in power loss. The losses are also proportional to the square of the frequency, so as frequency increases, eddy current losses increase too.

These losses can be reduced by using laminations in the core of the transformer which limit eddy current flow. However, this also affects the transformer’s efficiency and may result in increased power loss. To reduce these losses, designers must carefully balance size and efficiency requirements with cost considerations.

The losses of eddy current are an important factor. When designing a transformer and should not be overlooked as they can cause significant power loss if not properly managed.

Eddy Current Losses in Transformer

Calculation Method of Power Transformer Losses

Power transformer losses, also known as transformer losses, refer to the sum of energy dissipated by a transformer during the process of power transformation. These losses are mainly composed of two parts: iron loss and copper loss. Iron loss is caused by eddy current and hysteresis in the transformer’s core while copper loss is caused by the resistance of windings. In addition, there are other types of power losses such as stray loss and load loss which occur due to various external factors like temperature and humidity.

Calculation Method of Copper Loss

Calculating these total losses can be done using methods. Such as measuring voltages and currents or using mathematical models that take into account all the components in a power transformer. With this information, engineers can determine how much efficiency a given power transformer has and decide whether it should be replaced or not.

Variation of Transformer losses during operation

Transformer losses vary during operation, depending on the load and current. Loss in a transformer is made up of iron loss and copper loss. Iron loss occurs due to the flux passing through the core of the transformer and losses due to eddy currents generated in the winding which is known as the losses of eddy current. Copper loss is dissipated by the resistance of the winding and depends upon the square of the current.

At full load, these losses are maximum and at no load, these losses are minimum. Power factor also plays a role in determining transformer losses as it affects both iron and copper losses. Therefore, it is important to maintain good power factor to keep transformer losses low while operating a transformer.